Welcome to my Blog. This is the area where I post item that I find interesting or that I feel can help my clients. 

Some are strange, some are informational, some are downright scary...

Comments and/questions are always encouraged.

contact me

Wow.... what a Monday!

8/22/2016

1 Comment

 
Here is an excerpt from just one portion of my inspection today.... Needless to say, It was a long day and a heckuva Monday!
Crawl space floor is well below the exterior grade. Moisture stains are prevalent in the foundation walls. Evidence of constant water flow under the home. Sump pump installed. Most of the floor was covered in mold. Type unknown. These are signs of chronic moisture intrusion and poor ventilation. Hole at right side has evidence of water flowing through it and under the home. There is a roof valley termination above this area. See also exterior notes. The sump ejection pipe is also near this area, the water may be pumping out and flowing right back in. Recommend water restoration, mold remediator and/or hygienist design a remediation protocol for health concerns. Some of the piers under the original portion of the home have been undermined and settled. This would account for the many plaster cracks in the home interior. The left side of the home was a slab that was subsequently dug out and then supported by piers. The piers are dry laid, out of plumb, and not laid out in any recognizable pattern. The foundation wall from the original portion of the home has been broken out to allow access to this area. No lintel was installed and the wall above has displaced and is only being supported by the termite shield. Structural modifications made without engineering/permits cannot be expected to perform to a minimum standard. There are several modifications to this home where permitting was not available online. Recommend obtaining permitting records, plans, drawings, etc from seller to determine engineering, load carrying, code compliance etc. Future performance of these modifications unknown. Strongly recommend a structural engineer evaluate and design all repairs.
1 Comment

    Bo Passen

    Robert W. "Bo" Passen

    State Certified Home Inspector HI8396

    FABI Master  Professional Inspector
    RPI #0833

    ASHI Certified Inspector ACI #258588

    Certified Residential Thermographer
    ​CRT #2014061902

    International Assn of Certified Indoor Air Consultants   
    # IAC2-05-1848

    National Swimming Pool Foundation
    ​Certified Pool / Spa Inspector™ (CPI-585767) 

    352.530.7343 office 352.530.7361 cell


    sample inspection reports

    Archives

    January 2025
    October 2022
    October 2021
    May 2019
    December 2018
    November 2018
    June 2018
    December 2017
    October 2017
    June 2017
    February 2017
    December 2016
    November 2016
    August 2016
    July 2016
    June 2016
    May 2016
    February 2016
    January 2016
    December 2015
    November 2015
    October 2015
    September 2015
    August 2015
    July 2015
    June 2015
    May 2015
    April 2015
    March 2015

    Categories

    All

    RSS Feed

Picture
OFFICE: 352.530.7343                                 [email protected]                             CELL: 352.530.7361